Which crane brands used an iFlex system?

The iFlex system was used by several crane manufacturers, including FAUN, NPCC, SENNEBOGEN, TADANO, and XCMG. These brands installed the iFlex2 or iFlex5 safe load indicator as original equipment on specific crane models. If you operate one of these cranes and the iFlex system is reaching the end of its serviceable life, a direct replacement path exists through the DS130 or DS430 safe load indicator platform. This article covers what the iFlex system was, which brands used it, and what your options are today.

What was the iFlex system and what did it do?

The iFlex system is a crane safety system, specifically a safe load indicator (also known as a load moment indicator or rated capacity indicator), designed to monitor and control lifting operations. It measured the load on the crane, calculated the rated capacity for the current configuration, and prevented the operator from exceeding safe working limits. The system displayed live load data and triggered warnings or cutouts when limits were approached.

Safe load indicators like the iFlex are a core component of crane safety. They combine inputs from force sensors, angle sensors, and length sensors to calculate the actual load moment and compare it against the crane’s rated capacity chart stored in the system’s memory. The iFlex system performed this function for the specific crane models on which it was installed, providing the operator with a continuous readout of hook load, radius, and remaining capacity.

The system was also known in some markets as a rated capacity limiter or RCI, terms used interchangeably depending on the region and the applicable standard. Regardless of the name, the underlying function is the same: protect the crane, the load, and the people working around it.

Which crane manufacturers originally installed the iFlex system?

The iFlex system was installed as original equipment by a defined group of crane manufacturers. Based on our compatibility records, the following brands used the iFlex2 or iFlex5 variant on specific crane models:

  • FAUN (iFlex5)
  • NPCC (iFlex5)
  • SENNEBOGEN (iFlex2 and iFlex5)
  • TADANO (iFlex2 and iFlex5)
  • XCMG (iFlex2 and iFlex5)

It is worth noting that the iFlex was not the only PAT system used by these manufacturers. TADANO, for example, also had cranes fitted with the AS110, DS350C, DS350G, DS100, PRS145, and ECIS systems. SENNEBOGEN cranes appear with the DS350C, DS350G, DS100, PRS145, and PDC as well. This means that identifying the correct system on your crane requires checking the actual installed unit, not just the crane brand.

If you are unsure which system is fitted to your crane, the controller unit itself usually carries a type label. Alternatively, our field service team can assist with identification remotely or on site.

How does the iFlex system compare to modern crane safety systems?

The iFlex system performed its core function reliably for the cranes it was designed for, but modern crane safety systems offer significant advances in display technology, connectivity, data logging, and sensor compatibility. Today’s systems such as the DS130 and DS430 safe load indicators provide colour touchscreen displays, structured data logging, remote access, and support for current sensor standards including 4…20 mA outputs.

The practical gap between the iFlex and current systems becomes most visible in three areas:

Display and operator interface

Older systems used segment displays or early LCD panels. Modern indicators use high-resolution colour screens that present load data, radius, and capacity in a clear graphical format, reducing the chance of misreading under difficult lighting or weather conditions.

Sensor and connectivity standards

The iFlex relied on sensor types and communication protocols that were standard at the time of manufacture. Current systems support modern sensor outputs and can integrate with data logging platforms, mobile applications, and remote monitoring infrastructure. This matters for maintenance, calibration verification, and compliance documentation.

The functional requirement has not changed: the system must measure the load, compare it to the rated capacity, and act when limits are reached. What has changed is how precisely that function is performed, how the data is recorded, and how easily the system can be maintained over its service life.

What happens when an iFlex system reaches end of life?

When an iFlex system reaches the end of its serviceable life, the crane does not need to be taken out of service permanently. The steel structure of the crane remains sound, and the safety and control electronics can be replaced independently. An ageing or failing safe load indicator is a component issue, not a structural one.

In practice, end-of-life symptoms for any older crane safety system include display failures, sensor faults that cannot be cleared, loss of calibration data, or the inability to source replacement parts. When these issues occur on an iFlex system, the path forward is a controlled replacement rather than an unplanned breakdown.

A replacement project involves removing the existing controller and sensors, fitting a compatible modern system, loading the crane’s rated capacity charts into the new controller, and commissioning the system on the crane. The crane’s working envelope does not change. The operator interface changes, and the underlying safety logic is updated to current standards, but the crane continues to do the same work it was designed to do.

We have carried out similar projects on cranes of various ages and configurations. One example involved a crane built in 1998 where the original force transducers were no longer available. The solution was a DS130 safe load indicator controller combined with modern 4…20 mA force sensors, restoring full functionality without replacing the crane structure.

Can the iFlex system be repaired or recalibrated?

Repair and recalibration of the iFlex system are possible in some cases, but it depends on the specific fault and the availability of compatible components. PCB-level repairs can extend the life of an older controller if the failure is isolated to a repairable board and the rest of the system remains functional. Recalibration is possible as long as the sensors and controller are still operating within their specification.

The limiting factor is component availability. As systems age, the electronic components used in their manufacture become harder to source. When a PCB repair is no longer viable because the required components are not available, or when the sensor types used are no longer manufactured, repair stops being a practical option.

Our field service team carries out PCB repairs and calibration work on a range of older systems. Whether repair is the right choice depends on the fault, the age of the installation, and the overall condition of the sensors and wiring. We can assess this and give a clear recommendation on whether repair or replacement makes more sense for a specific installation.

What are the upgrade options for cranes that used the iFlex system?

Cranes that used the iFlex system can be upgraded to the DS130 or DS430 safe load indicator platform. Both systems are direct replacements for the iFlex2 and iFlex5 across all five crane brands listed above: FAUN, NPCC, SENNEBOGEN, TADANO, and XCMG. The DS130 is suited to most standard crane configurations, while the DS430 addresses more complex or multi-crane installations.

The upgrade process replaces the controller, display, and, where necessary, the sensors. The crane’s rated capacity charts are loaded into the new system during commissioning. From the operator’s perspective, the interface is updated and the functionality is maintained. From a compliance perspective, the crane is brought up to current safety system standards.

Beyond the controller itself, an upgrade project may also involve reviewing the connected sensors. Modern force sensors with 4…20 mA outputs offer better long-term stability and are easier to replace in the field than older sensor types. Our heavy-duty parts range includes load pins, load cells, and associated hardware for crane safety systems.

For crane owners and technical managers who want to understand the full scope of what an upgrade involves for their specific machine, the right starting point is a direct conversation with our team. We can review the existing installation, confirm compatibility, and outline what a replacement project would involve for your crane.

Contact us at PAT-Krüger to discuss a replacement for your iFlex system or any other legacy crane safety system. We will give you a straightforward assessment of your options.