What if the original force transducers are no longer available?

When the original force transducers fitted to your crane are no longer available, the crane does not have to go out of service. In most cases, the original transducers can be replaced with equivalent or custom-made units that match the mechanical interface, electrical output, and rated capacity of the originals. This applies whether the transducer is a load pin, a load cell, a line-rider, or any other type of force measurement device. The sections below walk through the most common questions crane owners, technical managers, and service engineers ask when they reach this point.

Why do force transducers become unavailable over time?

Force transducers become unavailable over time because the original manufacturer has discontinued the product, changed the design, or ceased trading entirely. This is a normal part of the industrial equipment lifecycle. A crane built in the 1990s or early 2000s may have been fitted with force measurement devices that were standard at the time but are now considered legacy components with no direct off-the-shelf successor.

Several factors drive this. Electronic components used inside a transducer, such as strain gauges, amplifier circuits, and connectors, have their own supply chains. When those components reach end of life, the finished product often follows. Changes in certification requirements, such as updates to ATEX or IECEx standards, can also make older designs impractical to manufacture without a full redesign. And when a manufacturer is acquired or merges with another company, product lines are frequently consolidated, leaving older models without support.

The result is that a perfectly serviceable crane structure can become dependent on a measurement component that nobody produces anymore. This is precisely the situation where a retrofit approach, replacing only the force measurement and control electronics while keeping the crane itself in service, becomes the most practical solution.

What are the risks of continuing to use a failing or outdated transducer?

Continuing to operate with a failing or outdated force transducer introduces direct safety and compliance risks. If the transducer provides inaccurate load readings, the crane’s safe load indicator or load moment indicator cannot protect the crane or its operators from overload. A transducer that drifts, drops signal, or fails intermittently is more dangerous than one that has failed completely, because the system may appear to be working while the readings are unreliable.

From a compliance perspective, crane safety systems in most jurisdictions must be maintained in full working order and verified through regular calibration. An obsolete transducer for which no calibration standard or replacement seal exists creates a documentation problem that can affect the crane’s operating certificate. In offshore and heavy-lift environments, where certifications are audited regularly, this is a practical operational risk, not just a theoretical one.

There is also a secondary risk: when a transducer fails completely during a lift, the entire crane may be taken out of service at short notice. If no replacement is available from stock and no retrofit plan is in place, the downtime can extend significantly while a solution is sourced. Planning the replacement before failure occurs is always more cost-effective than responding to an emergency.

Can a force transducer be replaced with a different brand or model?

Yes, a force transducer can be replaced with a unit from a different manufacturer or a different model series, provided the replacement matches the key parameters of the original. The most important of these are the mechanical interface, the rated capacity, the electrical output signal, and the environmental protection rating. If all four align, the replacement will function correctly within the existing crane safety system.

In practice, the electrical output is often the most flexible parameter. Many modern crane controllers, including the DS130 safe load indicator and DS430 safe load indicator in our DSx30 platform, accept standard analogue signals such as 4 to 20 mA, which are widely used in industrial force measurement. A crane built in 1998 that originally used proprietary force transducers can, for example, be retrofitted with modern 4 to 20 mA force sensors connected to a DS130 controller, restoring full load monitoring functionality without modifying the crane structure.

Where the mechanical interface is non-standard, such as with a load pin that was machined to a specific diameter and shear configuration, an off-the-shelf replacement may not exist. In those cases, a custom-made transducer is the appropriate route.

What is a custom-made force transducer and when is one needed?

A custom-made force transducer, also called a bespoke force sensor, is a measurement device designed and manufactured to meet a specific set of dimensional, capacity, and output requirements that no standard product satisfies. It is needed when the installation geometry, the load path, or the required capacity falls outside the range of catalogue products.

Common situations where a custom transducer is the right answer include:

  • A load pin that must fit a specific pin diameter and clevis geometry on an existing crane hook block or sheave assembly
  • A compression load cell that must fit within a defined height envelope in a weighing structure
  • A force measurement device that must carry dual or redundant outputs for a safety-critical application
  • A sensor that must be certified to ATEX, UL, or IECEx standards for use in a hazardous area
  • A line-rider or dynamometer intended for a specific wire rope diameter and working load

We design and manufacture custom force sensors from 50 kg up to 1,000 tonnes capacity, covering load pins, load cells, pressure pots, strain gauge assemblies, compression load cells, line-riders, and dynamometers. Units are available in stainless steel with single or redundant outputs, and can be supplied with ATEX, UL, or IECEx certification where required. These are listed among our heavy-duty parts and are built to the specific dimensional and output requirements of each installation.

How does the replacement process work for a discontinued force transducer?

The replacement process for a discontinued force transducer follows a structured sequence: gather the technical data from the existing installation, identify whether a standard or custom replacement is suitable, manufacture or source the unit, and carry out installation and calibration. The process is essentially the same whether the transducer is being replaced as a planned upgrade or as an emergency response to a failure.

Assessment and matching

The first step is to characterise the existing transducer fully. This means recording its physical dimensions, the load range it was designed to measure, its electrical output type, its connector specification, and any certification markings. If the unit is still partially functional, a calibration check against a known reference load provides useful baseline data. If it has failed completely, the crane’s original documentation, data plates, or wiring diagrams become the primary source of information.

Sourcing or manufacturing the replacement

Once the specification is established, the replacement is either sourced from available stock or manufactured to order. For common configurations, such as standard load pins in popular diameter ranges or load cells with 4 to 20 mA output, lead times are shorter. For fully custom geometries or units requiring hazardous-area certification, the manufacturing process takes longer. The replacement unit is calibrated before dispatch and supplied with a calibration certificate traceable to national standards.

Installation and system verification

Installation is carried out by a qualified engineer, either on site or with remote guidance depending on the complexity of the installation. After fitting, the complete load measurement chain, from the transducer through the cabling to the controller display, is verified against known test loads. Our field service team supports installations worldwide, including offshore locations and remote sites.

What information is needed to source or manufacture a replacement?

To source or manufacture a replacement force transducer, the most important information is the physical dimensions of the existing unit, its rated capacity, its electrical output specification, and the environmental conditions it operates in. Providing this data at the start of the process avoids delays and ensures the replacement fits correctly without modification to the crane structure.

The following information is useful to have available:

  • The original part number or manufacturer designation, even if the product is no longer available
  • Dimensional drawings or physical measurements of the transducer body, pin diameter, thread sizes, and mounting points
  • The rated capacity in tonnes or kilonewtons, and the overload rating if known
  • The electrical output type, for example millivolt per volt, 4 to 20 mA, or frequency output
  • The supply voltage and connector type used in the existing installation
  • Any certification requirements such as ATEX zone classification or IECEx marking
  • The cable length required and whether the cable must be armoured
  • The operating environment, including temperature range, exposure to saltwater, and whether the unit is submerged

If drawings are not available, we can work from physical measurements taken from the existing unit or from photographs of the installation. The more complete the information provided, the faster and more accurately a replacement can be specified.

How long does it take to get a custom force transducer made?

The lead time for a custom force transducer depends on the complexity of the design, the materials required, and whether hazardous-area certification is needed. A straightforward custom load pin in a standard material with a 4 to 20 mA output can often be manufactured more quickly than a fully certified ATEX unit with a complex geometry. Exact lead times depend on the specific requirements of each order and cannot be stated as a fixed figure without a detailed specification.

In general, the factors that extend lead time are: non-standard materials such as duplex stainless steel or titanium, dual or redundant output configurations that require additional internal wiring, certification testing for ATEX or IECEx approval, and cable assemblies with armoured or subsea-rated construction. Where a crane is out of service and the replacement is urgent, it is worth discussing the situation directly so that priorities can be assessed and, where possible, the process expedited.

Planning ahead reduces this pressure considerably. If a transducer is showing signs of drift, instability, or physical wear, initiating the replacement process before it fails completely gives enough time to manufacture the correct unit without compromising crane availability.

If the force transducers on your crane are no longer available or are showing signs of age, we are ready to help you find a practical path forward. Contact PAT-Krüger to discuss the specifics of your installation, and we will work with you to identify the right replacement solution, whether that is a standard unit from stock, a custom-made sensor, or a full retrofit of the load measurement and control system.